Features
5-part blood cell counter
25 parameters +3 histogram+1 3D scattergram
2 test mode
60 samples/hour
14'' large touch screen
External USB printer
Support LIS system
Stable, durable and economical
Performance
1. High Stability & Accuracy
Advanced Sweep-Flow technology guarantees low PLT samples counted precisely.
Combined with optical and impedance method to make the BASO measurement more reliable and stable
Creative SMART-FLOW fluidic technology to makes SMART-II with good reliability and free of maintenance.
2. User-friendly System
1. 14 inch touch screen with high resolution and sensitivity, can be operated by wearing gloves
2. ONE touch to start the test,
3. ONE click to remove error,
4. ONE screen for most of the daily operation.
5. Intelligent turn off power switch.
3. Cost-effective and Attractive Design
Low running cost, only three reagents needed for the test ,
Low reagent consumption for single test.
Low volume sample consumption
CBC+DIFF mode:≤20ul, CBC mode:≤10ul, ideal choice for pediatrics and geriatrics.
Technical Specifications
Principle
Tri-angle Laser scatter
3D Scattergram analysis
Flow Cytometry method
Cyanide free reagent for HGB test
Impedance method for RBC and PLT counting
Parameters
25 Reportable parameters: WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, MPV, PCT, PDW, P-LCR, P-LCC, NEU%, LYM%, MON%, EOS%, BAS%, NEU#, LYM#, MON#, EOS#, BAS#
1 3D Scattergram
3 Histograms(WBC/BASO, RBC, PLT)
4 Research parameter: ALY%, ALY#, IG%, IG#
Throughput: 60 samples per hour
Test Mode:
CBC mode, CBC+DIFF mode
Venous whole blood, Capillary whole blood and Prediluted
Sample Volume:
CBC+DIFF mode: ≤20ul
CBC mode: ≤10ul
Display: 14 inch touch screen, resolution 1366*76
Storage: Up to 100,000 results(including histogram, scarttergram, patient information
Printout: Support various external USB printers, printout formats user definable
Communication: Bi-direction LIS, support HL7 protocol Internal RFID reader
Interface:1 LAN port, 4 USB ports
Working Conditions: Temperature:10-30℃
Humidity: 20% - 85%
Air pressure: 70~106kPa
Working latitude: ≤3500m
Power supply:AC100-240v,50/60HZ
Dimension: 480x375x517mm(L*W*H)
Weight: 36Kg(net)
2. SY-B006 5 Diff Blood Corpuscle Analyzer Auto Blood Chemistry Analyzer
The SY-B006 5 Hematology Analyzer offers time and resource savings, eliminates manual intervention, and produces high-quality results even for patient groups with challenging draw.
Technical Specifications
Parameters:
27 parameters: WBC, LYM%, MON%, NEU%, EOS%, BAS%, LYM#, MON#, NEU#, EOS#, BAS#, RBC, HGB, HCT, MCV, MCH, MCHC, RDW_CV, RDW_SD, PLT, MPV, PDW, PCT, P_LCR, RETIC%, RETIC_ABS, IRF
2 Histograms for RBC and PLT
2 Scatter grams: 5-part differential scatter gram
Eosinophils and Neutrophils scatter gram
2 3-D stereograms
Principles of operation:
WBC 5-part:Flow Cytometry(FCM)+ 4 angles laser light scatter
WBC Analysis: Optical and impedance measurements
RBC/PLT Analysis: Impedance method
HGB test: Cyanide-free reagent colorimetry
RET test: Flow Cytometry(FCM)+laser light scatter+Chemical dye method
Sampling modes: Auto loader 160uL·Manual mode 160uL,Pre-diluted mode 40ul
Aperture Diameter: WBC 100um·RBC/PLT 80um
Throughput: Auto loader up to 110 samples per hour
Manual mode up to 100 samples per hour
Sampling device: Automatic sampling device with a capacity of 120 samples,
10 samples×12 racks, auto built-in barcode reader
Display: PC display with Linux system,14 inch color TFT display
Dimension: 760MM×684MM×676.5MM
·Laser light multi-dimensional cell classification
·Double mode for WBC counting (Impedance Count and Optical Count)
·Resistant RBC mode
·Sample rotatory valve quantification technique
·Up to 110 samples per hour
·Walk-away automation, high efficiency and accuracy
·WBC 5 part diff with sheath reagent only
3. Automatic Blood Grouping Instrument PLS-MY-B006K
Using procedures like ABO grouping, Rh typing, antibody screening, and cross matching, an automated blood grouping machine can identify a person's blood type. The presence or absence of the two antigens A and B allows for the division of blood grouping systems into four categories. Testing for blood groups can be done manually or automatically using instrumentation systems. Red cells are initially immobilized onto a solid support medium made of polystyrene for the Solid Phase Red Cell Adherence Assay (SPRCA). The foundation of erythromagnetic technology is the utilization of paramagnetic particles that have been adsorbed on RBC surfaces. For blood type prior to a blood transfusion or for donor screening, automated blood grouping devices are mostly employed in hospital blood banks and blood transfusion/donor centers for blood typing prior to a blood transfusion or when classifying a person’s blood for donation.
For Micro-gel Blood Grouping Test
Test application
ABO / RhD blood group detection (forward ), ABO / RhD blood grouping test (reverse)), RhD blood grouping antigen test (RhD genotyping), anti-human globulin test (cross matching), anti-human globulin test (irregular antibodies), anti-human globulin classification test (IgG / C3d allergy) test;
Image collection and results analysis automatically;
*Test Speed: 80 tests / hour;
*customizing incubation time, centrifugation speed and centrifugation time on request;
*Reagents &sample:Support bar code scanning and location identification;
*Bilateral LIS, support, manual / automatic result acquisition ,;
*Flexible and customized printing function
Features
1. MODEL on table
2. Outline Dimension 1320(L)X870(W)X965(L)
3. Weight 260KG
4. Inspection Speed Up to 80 tests/Hour
5. Reagent Area 12 reagent, shake well
6. The sample area 96 samples, continuous loading, bar code scanning, support a variety of mainstream code system, can be loaded in succession
7. Cleaning port To clean the double needle
8. Disinfection area Two bottles, is used to disinfect double needle (not required)
9. Diluent area Two bottles, is used to dilute of red blood cells
10. Blending area 96 - well plates, used to dilute samples of red blood cells
11. Incubate area Can incubate 24 reagent card at the same time
12. Reagent card rack area 60 reagent card storage, can be loaded in succession
13. Pierce area Complete the prick reagent card automatically
14. The centrifuge One centrifuge. 24 reagent screens; Automatic centrifugal
15. Robot One; Automatic scratch card, Pierce, barcode scanning
16. Sampling needle Double needle with liquid level detection sensor, automatic detection samples, diluent, reagent level
17. The user software Windows xp/Windows 7 operating system, in both Chinese and English operation interface, abnormal information identification, tips, man-machine dialogue, reagent project added at any time, to use to.
4. Mayamed Medical Equipment Lab Automatic Blood Test Machine Auto Hematology Analyzer PLS-MY-B003
The PLS-MY-B003 Hematology Analyzer uses patented VCS technology to provide precise findings for the initial analysis. Its sophisticated analyzer optimizes operations to maximize laboratory staff time with fewer slide checks and strong system dependability for optimal uptime. The analyzer can be combined with automation and clinical informatics programs to create scalable, unique solutions.
Features
Flexible and Easy To Use
Fully automatic analysis cycle.
Automatic internal and external probe cleaning)
High Reliability and Safety
Total Solution For QC and Calibration
Comprehensive QC programs including L-J , auto draw and print QC graph
Automatic and manual calibration
Unique calibration program with fresh blood
Customizable software is available
Huge storage of 30,000 patient with histogram
Easy to check the patience data
Programmable multi-format printout
Specification
Test principle
|
Electrical resistance for counting and
Cyanide free method for HGB
|
Clot clear
|
High voltage burn and high pressure flush
|
Sample volume
|
whole blood : 9.8μl, prediluted : 20μl
|
Aperture diameter
|
WBC: 100μ m, RBC,PLT: 70μ m
|
Chambers
|
Two chambers
|
Throughput
|
60 samples/hour
|
Language
|
English, Spanish, French, and Chinese
|
Reference range type
|
newborn, children, male, female and general
|
Display
|
10.4 inch color touch screen, show all parameters and histograms
|
Input and output
|
USB, keyboard, mouse, Parallel Port,RS232
serial port, can be connected to the network by external computer.
|
Working Environment
|
Temperature:10℃~35℃;Humidity:≤85% RH
|
Voltage
|
AC 110 V~240V,50Hz/60 Hz±1Hz ,Auto adapt
according to the input voltage
|
Dimension
|
370mm×435mm×472mm
|
Net weight
|
30Kg
|
Parameter
Parameter
|
Linearity
|
Precision(CV%)
|
WBC(109/L)
|
0.3~99.9
|
2.5(7.0~15.0)
|
RBC(102/L)
|
0.20~8.0
|
2(3.5~6.0)
|
HGB(g/L)
|
10~250
|
1.5(110~180)
|
MCV(FL)
|
|
0.5(80.0~110.0)
|
PLT(109/L)
|
10~99.9
|
5(150~500)
|
Carry over
|
WBC≤0.5% RBC≤0.5%
HGB≤0.5% PLT≤1%
|
5. Medical Laboratory Blood Coagulate Machine Full Automatic Coagulation Analyzer PLS-MY-B032C
The blood coagulation analyzer uses optical colorimetry as its detecting method. After the reagent and plasma are combined, fibrinogen is changed into fibrin and coagulated, which changes the test specimen's optical density and allows the device to detect the end point of coagulation.
Application:
Prothrombin time (PT), activated partial thromboplastin time (APTT), thrombin time (TT), and fibrinogen (FIB) can all be detected with this method in plasma.
extensively used in blood labs, biochemical labs, hospital blood labs, and other labs.
Technical Parameters
*Test Method: optical method, magnetic beads method
*Test Item: APTT, TT, PT, FIB and blood coagulation factors, coagulation-related special items e.g. D-dimer and FDP
*Test Speed: 260Ts/h
*Sample Site: 48
*Reagent Site:55
*Pre-heating Site:20
*Probe: 2
*Washing Site: 2
*Sheathed Manipulator: 1
*Automatic and manual dual-mode test capability
*Insufficient cuvette and reagent alarm function
*Tilt reagent position(extend the use time of reagent to avoid waste and ensure the accuracy of the test results)
*Reagent position with refrigeration function
*Sampling probe with liquid surface induction and constant heating function
*Display coagulation curve of dynamic test
*PT-derived FIB function
*Automatic or manual calibration function
*LED work lighting function
*Batch test and emergency priority insertion test function
*Abnormal test results alarm and automatic retest function
*Insufficient test results alarm and waste liquid overflow alarm function
*Bar code recognition function(optional)
*Sheathed manipulator definitely avoids the risk of cuvette to be fallen off in the transposition process through gripping
*Four directions ventilation and cooling function, makes it reliable operation
*Infinite storage for test and quality control data
*Cuvette loading capacity: 1000 cups
*Any sample position has the function of emergency priority inserting
*Drawer-style loading system
*Immediate scanning transmission, then enter patient information soon
*Waste container, reduces pollution